1.
Int J Prosthodont ; 37(1): 109, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381990

RESUMO

PURPOSE: To evaluate the in vitro accuracy of impressions obtained with two silicone and corresponding stone models using two laboratory scanners. MATERIALS AND METHODS: A master model with synthetic resin teeth with two single-unit crown preparations was created and scanned using a 12-megapixel scanner. Five conventional impressions of the physical model were prepared with different silicone impression systems (Zhermack and Coltene) using the double-mix technique and poured with gypsum. The impressions and stone models obtained were scanned using two extraoral scanning systems (Identica T500, Medit; S600 ARTI, Zirkonzahn). All best-fit superimpositions of the teeth areas were conducted between the master model and the scans of the impressions and models obtained with the two scanners. A P < .05 level was considered significant. RESULTS: The Identica T500 Medit scanner showed an accuracy of 102.34 (89.67, 115.01) µm for Coltene silicone and 79.51 (67.82, 91.21) µm for Zhermack silicone, while the S600 ARTI Zirkonzhan scanner presented 110.79 (98.24, 123.33) µm and 91.91 (81.29, 102.54) µm, respectively, with significant differences between scanners for Zhermack silicone (P = .008) and for the corresponding stone models (P = .002). Zhermack silicone presented overall discrepancies lower than Coltene silicone, with statistically significant differences in both scanners analyzed (P < .001; P = .017). However, the discrepancies found were within clinically acceptable values. With the Zirkonzahn scanner, discrepancies found in the Zhermack impressions were lower than in the corresponding stone models (P < .001). CONCLUSIONS: The direct digitization of silicone impressions with laboratory scanners presented comparable results to conventional techniques with stone models.


Assuntos
Imageamento Tridimensional , Dente , Silicones , Técnica de Moldagem Odontológica , Desenho Assistido por Computador , Materiais para Moldagem Odontológica
2.
J Prosthet Dent ; 130(1): 87-95, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34711406

RESUMO

STATEMENT OF PROBLEM: Microgap and bacterial microleakage at the implant-prosthetic abutment interface are recognized concerns for implant-supported restorations, leading to inflammation of the peri-implant tissues, with deleterious consequences for crestal bone levels. However, little is known regarding the interface established between the implant and the healing abutment or cover screw placed for the osseointegration phase. PURPOSE: The purpose of this in vitro study was to characterize the implant-cover screw and implant-healing abutment interfaces of a platform-switched implant system to determine the microgap and bacterial microleakage of the system and evaluate the biological response and functionality of an interface sealing agent. MATERIAL AND METHODS: The interfacial microgaps of the implant-healing abutment and implant-cover screw interfaces were characterized by scanning electron microscopy (n=10), and bacterial microleakage was evaluated after colonization with Enterococcus faecalis in a 30-day follow-up (n=10). The sealing efficacy and irritation potential of a silicone-based sealer were determined by using the hen's egg test on chorioallantoic membrane assay. The 2-sample t test was performed to compare means between groups, and data presented with the Kaplan-Meier method were compared statistically by using the log-rank test (α=.05). RESULTS: The interfacial microgap was less than 2.5 µm for both systems. Bacterial microleakage was noted in approximately 50% of the specimens, particularly at early time points, at both the healing abutment and cover screw interfaces. The silicone-based sealer prevented bacterial leakage in the experimental setting. CONCLUSIONS: The implant-healing abutment and implant-cover screw interfaces of the tested system, despite the low microgap, allowed for bacterial microleakage after internal colonization. The use of a nonirritating silicone-based sealing agent effectively sealed the system.


Assuntos
Implantes Dentários , Osseointegração , Animais , Feminino , Galinhas , Dente Suporte , Implantes Dentários/microbiologia , Bactérias , Projeto do Implante Dentário-Pivô
3.
J Esthet Restor Dent ; 34(8): 1147-1155, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36052667

RESUMO

BACKGROUND: The prosthetic screw fixes the prostheses to the implants. Upon osteointegration, the untightening of the prosthetic screw is the most common problem in oral rehabilitation with implants. OBJECTIVE: To study the deformation of the implant retaining hexagonal screw head. METHODS: This investigation used two methods for evaluating the screw head's area of deformation (mm2 ): a stereoscopic microscopy and micro computed tomography (microCT). For stereoscopic microscopy, 16 titanium alloy (T) and 16 titanium gold-plated alloy (G) screws of the Zimmer Biomet™ brand were used, divided into eight groups: group 0 (control group), groups T1 and G1 (screws tightened 10 times to 20 Ncm), the groups T2 and G2 (screws tightened 20 times to 20 Ncm) and the groups T3 and G3 (screws tightened 10 times to 30 Ncm). In the study with microCT, one screw was randomly chosen from each of the groups described above to perform the scanning by microCT. RESULTS: When comparing the type of screw material using stereoscopic microscopy, no statistically significant differences were found (p > 0.05). Contrarily, different number of successive grips and different torque value showed statistically significant differences in the head section of the retaining screws (p < 0.05). The observation by microCT showed the torque applied is crucial to the head deformation in titanium screws. In gold-plated screws the successive tightening appears to be pivotal. CONCLUSION: Titanium and gold screws tend to behave similarly. By increasing the tightening cycles and the torque values of protocols greater levels of deformations can be expected. In general, microCT data showed better results for gold-plated titanium alloy. CLINICAL SIGNIFICANCE: To control severe screw head deformation and the impossibility of untightening the implant's restoration, clinicians should avoid extreme torque values and prevent surpassing 10 tightening cycles.


Assuntos
Implantes Dentários , Retenção em Prótese Dentária , Dente Suporte , Análise do Estresse Dentário/métodos , Microtomografia por Raio-X , Titânio , Microscopia , Ligas de Ouro , Ligas , Ouro
4.
Odontology ; 110(2): 231-239, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34448952

RESUMO

The present study aims to characterize, for the first time, the microgap and bacterial microleakage of a platform-switched implant system with hybrid connection, screwed at distinct torque values (manufacturer recommended torque-25 N cm-and a reduced torque-5 N cm-mimicking the long-term functional use), in the absence or presence of a silicon-based sealing agent. Microgap was determined through scanning electron microscopy and bacterial microleakage was evaluated in vitro, upon Enterococcus faecalis colonization of the system. The sealing efficacy was evaluated in the absence or presence of a commercially available silicon-based sealer. The cytotoxicity of the sealer was further addressed in vitro, with a fibroblastic cell line, in accordance with reference standards. A low microgap of the implant system was verified, regardless of the applied torque load-maximal values ranged around 0.25 and 1.25 µm, for 25 and 5 N cm torques, respectively. No bacterial microleakage was reported at 25 N cm, while at 5 N cm, leakage was verified on 38% of the samples. The application of a silicon-based sealer-with an adequate cytocompatible profile-was effective on preventing the bacterial microleakage on the assayed experimental setting. The assayed platform-switched implant system with hybrid connection presented a low interfacial misfit and an effective sealing capability at manufacturer recommended torque. Despite the increased microleakage at low torque conditions, the application of a cytocompatible silicon-based sealing agent restored the sealing effectiveness of the system. The use of a silicon-based sealing agent can assist on the maintenance of the sealing effectiveness even at low torque conditions.


Assuntos
Implantes Dentários , Infiltração Dentária , Dente Suporte , Projeto do Implante Dentário-Pivô , Infiltração Dentária/microbiologia , Infiltração Dentária/prevenção & controle , Humanos , Silicones , Torque
5.
J Prosthodont Res ; 61(4): 439-449, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28223139

RESUMO

PURPOSE: Implant-supported overdentures are an alternative predictable rehabilitation method that has a high impact on improving the patient's quality of life. However, some biological complications may interfere with the maintenance and survival of these overdenture implants. The goal of this article was to assess the factors that affect peri-implant success, through a hypothetical prediction model for biological complications of implant overdentures. METHODS: A retrospective observational, prevalence study was conducted in 58 edentulous Caucasian patients rehabilitated with implant overdentures. A total of 229 implants were included in the study. Anamnestic, clinical, and implant-related parameters were collected and recorded in a single database. "Patient" was chosen as the unit of analysis, and a complete screening protocol was established. The data analytical study included assessing the odds ratio, concerning the presence or absence of a particular risk factor, by using binary logistic regression modeling. Probability values (p values) inferior to 0.05 were considered as representing statistically significant evidence. RESULTS: The performed prediction model included the following variables: mean probing depth, metal exposure, IL1B_allele2, maxillary edentulousness, and Fusobacterium nucleatum. The F. nucleatum showed significant association with the outcome. Introducing a negative coefficient appeared to prevent complications or even boost the biological defense when associated with other factors. CONCLUSIONS: The prediction model developed in this study could serve as a basis for further improved models that would assist clinicians in the daily diagnosis and treatment planning practice of oral rehabilitation with implant overdentures.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Revestimento de Dentadura , Interleucina-1/genética , Polimorfismo Genético , Idoso , Idoso de 80 Anos ou mais , Implantes Dentários/efeitos adversos , Prótese Dentária Fixada por Implante/efeitos adversos , Revestimento de Dentadura/efeitos adversos , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Pseudallescheria , Estudos Retrospectivos , Fatores de Risco
6.
Rev. odontol. UNESP ; 35(2): 183-189, abr.-jun. 2006. tab, ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-512566

RESUMO

O desenho de uma estrutura protética num computador seguido da sua confecçãopor uma máquina de fresagem é designado comumente por CAD-CAM. Essa tecnologia temtrazido uma evolução muito grande na Odontologia nos últimos 20 anos com o objetivo principalde otimizar a produção de estruturas protéticas. A evolução dos sistemas CAD-CAM tem sidoacompanhada também pela evolução dos materiais, sobretudo da zircônia, a cerâmica maisresistente disponível nessa área. Entre os sistemas CAD-CAM para a Odontologia, este trabalhorealça o Cerec®, o Procera®, o Lava® e especialmente o Everest®, sistema da Kavo® existente naFaculdade de Medicina Dentária da Universidade do Porto, Portugal.


The virtual design of a structure, followed by its machining in a milling unit isnormally called as CAD-CAM. This technology has evolved greatly in Dentistry in the last 20years, with the main purpose of optimizing the production of prosthetic structures. Together withthe evolution of this systems we can observe the changes in dental materials, specially zirconia,the most resistant ceramic available in Dentistry. Within this CAD-CAM systems this manuscriptwill focus the Cerec®, the Procera®, the Lava®, and specially the Everest®, from Kavo® corporation,which exists in the Dental Faculty of Porto University, Portugal.


Assuntos
Materiais Dentários , Planejamento de Prótese Dentária , Prótese Parcial Fixa , Tecnologia Odontológica , Zircônio